UPS EVO DSP PLUS 1200 RACK TOWER – Power 1,200 VA PF 0,9. On Line Technology (VFI) DSP, 94% Efficiency, Input / output 230 / 230Vac 50 / 60Hz, IEC Output Sockets. The UPS EVO DSP PLUS 1200 RACK has the below features.
- Complete protection from blackout, voltage fluctuations (overvoltages and undervoltages), lightning (with upstream arrester), frequency variations, surges, harmonics, voltage distortions
- Recommended for Data Centers, Local Area Network (LAN ), Electro-medical, Industry processes, Virtual servers, Pellet stoves, Thermo-fireplaces, Boilers for home heating
- Convertible format (Rack 19″ or Tower) with adjustable display
- Hot Swap batteries
- Intelligent slot for SNMP card o Dry Contact
- On-Line Double Conversion technology transformerless (VFI-SS-111)
- Active PFC circuit (0.99)
- Compatibility with generating set
- Battery charging system managed by microprocessor
- Static bypass
UPS EVO DSP PLUS 1200 RACK TOWER – Power 1,200 VA PF 0,9. On Line Technology (VFI) DSP, 94% Efficiency, Input / output 230 / 230Vac 50 / 60Hz, 8 IEC C13 sockets, dimensions 43.8×8.8×31 cm (2U), weight 12 Kg, bacup time 10 min, including 2 batteries for 12Vdc 9AH. Positioning in 19 “rack or tower, multifunction graphic LCD display, static bypass, hot swap battery, EPO connector, USB and RS232 communication ports, for UPS control and on / off programming via the free TecnoManager software. SNMP card or Dry Contact (optional).
Technical data
Code | FGCEDP1202RTIEC |
Nominal Power | 1.200 VA |
Active power | 1.080 W |
Power factor | 0,9 |
Technology | On-Line Double Conversion transformerless (VFI-SS-111) |
Cooling | Fan cooling |
Audible noise | < 45 dBA at 1 m |
Positioning | Tower positioning or Into 19’’ rack (2U) |
Dimension (UPS) WxHxD | 43,8×8,8×31 cm |
Dimension (with packing) WxHxD | 50x18x40 cm |
Wight | 12 Kg |
Input | |
Number of phases | 1Ph+N |
Nominal voltage | 208Vac/220Vac/230Vac/240Vac |
Input voltage range | 110-300Vac |
Nominal frequency | 50/60 Hz (selectable) |
Input frequency range (On-Line mode) | +/- 7% |
Input power factor | 0,99 |
Output | |
Number of phases | 1Ph+N |
Nominal voltage | 208Vac/220Vac/230Vac/240Vac (selectable) |
Static voltage Regulation at %100 linear load (On-Line and battery mode) | ±1% |
Voltage THD at rated linear load | <2% (linear load), <8% (non-linear load) |
Crest factor | 3:1 |
Frequency | 50/60 Hz (selectable) |
Free running frequency | ±0,2 Hz |
Inverter waveform | Sinewave |
Overload capability | 110% only audible warning, 110-130% for 30 sec, >130% for 100 ms |
Efficiency | 94%, calculated in double conversion modeto 100% load according to standard 62040-3 |
Transfer time | 0 ms (On-Line) |
Battery | |
Type | Lead acid, sealed, maintenance free |
Backup time (Typical) | 10-30 min |
Extended autonomy | No |
Environmental specification | |
Working temperature | From 0 to 55 °C (recommended from 20 to 25 °C) |
Humidity | < 95% without condensation |
Maximum altitude | 3000 m |
IP protection | IP20 |
Certifications | CE (Standards: Low Voltage Directive IEC EN 62040-1; EMC Directive IEC EN 62040-2; classification IEC EN 62040-3) |